new original warranty: one year in stock sophia@swanautomation.com
View Morenew original warranty: one year in stock sophia@swanautomation.com
View Morenew original warranty: one year in stock sophia@swanautomation.com
View Morenew original(warranty: one year ) in stock sophia@swanautomation.com
View MoreAllen Bradley 20F11NC030AA0NNNNN PowerFlex 753 Frequency AC drive The 20F11NC030AA0NNNNN built by Allen Bradley (AB) is a 15 kW module. This VAC drive includes optional communication slot built-in, is a 400VAC/540V DC VFD, and has an IP20/IP00 (NEMA UL Type Open) enclosure type. Also, it has an amperage output rating of 30 Amp. Furthermore, it comes with a dynamic brake included in the VFD in case braking is required. Additionally, this Rockwell Automation frequency drive has no HIM unit included, instead the drive comes with a plastic cover.
View MoreAllen Bradley 20F11NC022JA0NNNNN PowerFlex 753 Frequency AC drive The Allen-Bradley 20F11NC022AA0NNNNN drive is an air-cooled drive with an open enclosure. It is part of the PowerFlex 753 drive series. The 20F11NC022AA0NNNNN operates with 400 Volts AC and 540 Volts DC voltage.
View MoreAllen Bradley 20F11NC022AA0NNNNN PowerFlex 753 Frequency AC drive The Allen-Bradley 20F11NC022AA0NNNNN drive is an air-cooled drive with an open enclosure. It is part of the PowerFlex 753 drive series. The 20F11NC022AA0NNNNN operates with 400 Volts AC and 540 Volts DC voltage.
View MoreAllen Bradley 20F11NC015JA0NNNNN PowerFlex 753 Frequency AC drive The Allen-Bradley 20F11NC015AA0NNNNN drive is a PowerFlex 753 series drive. It is rated for 400 Volts AC or 540 Volts DC nominal voltage. It has an operating current rating of 15.4 Amps.
View MoreNew original (warranty: one year) in stock
sophia@swanautomation.com
Item NO.:
1756-PAR2Order(MOQ):
1Payment:
T/T wire transfer , Western UnionProduct Origin:
USAColor:
NewShipping Port:
HK Shanghai Shenzhen GuangzhouLead Time:
3 days (if in stock)1756-PAR2
1756-PAR2
1756-PAR2
Contact detail:
Mobile/ WeChat/ WhatsApp:+86-17354319552
E-mail:sophia@swanautomation.com
Skype: sophia_9090@163.com
QQ: 2747366625
Contact: Sophia
Shipping & Payment:
1.Shipping will be made via DHL,TNT,EMS,FedEx or USP .
If you would like to use your shipping account number please contact us with that information.
2.We Ship after receiving payment from the buyer.
3. All the goods will be tested before shipment ,we will track the goods until you received.
4.Payment: T/T Western Union
5.New original with one year warranty
Feedback:
We want our customers to be completely satisfied with their purchase. If anything about your transaction is not your satisfaction. Please contact us before leaving Feedback. It gives both the parties the chance to get positive trading experience in future.
Sales of the brand:
1.BENTLY NEVADA Bentley 3500 monitoring system: 3500/22M 3500/53 3500/45 3500/15 3500/25 3500/20 3500/42M 3500/33 3500/32 3500/50 3500/50M
2.Schneider/Modicon (140CPU67160,140CPU43412A,AS-BADU-205,....)
3.Siemens:(6DD,S-200,S-300,S-400,S-1500,S5,S-1200,SIMADYND,Siemens Moore,VIPA PLC ...)
4.GE (General Electric): IC693/IC697/IC698/IS200/DS200/IS215 modules, cards, drivers and other spare parts.
5.ABB S800 module AI810/CI830/DI810/DO810/AO810/DO820/DI821/TU831V1 DCS system AC800F controller EI803F.FI830F.FI810F.PM856K01.PM802F.PM802F.PM825.
6.InvensysTriconex: 3700A/3805E/4351B/3503E/3625/3008/4119A/8312/3703E/3511/redundant fault-tolerant control system, the most modern fault-tolerant controller based on triple modular redundancy (TMR) structure
7.Rockwell AB 1756.1747.1746.1769 1794 1771 1785 series PLC module
8.Foxboro FCP270 FB201 FBM202 FBM204 FBM237 FBM242 FBMSVH FBMSSW module, matching terminal cable
9.Westinghouse Ovation system | Westinghouse Emerson DCS process control conditions
10. YOKOGAWA (CP345,CP451-10,AMM12C,AAI141-S00...)
11.FOXBORO (FCP270,FBM217,FBMSVH,FBMSSW,FBM213...)
12. BACHMANN (MPC240,CM202,DI232,MPC240,NT255,AIO288...)
13.Honeywell(CC-PAIH02,FC-SAI-1620M,MC-TAOY22,CC-PDOB01,CC-PAOH01 51405039-175 .
14.Emerson Ovation (1C31194G01,1C31197G01,5X00106G01,1C31125G02...)
1756-LSP | 1746-A10 |
1756-M02AE | 1746-A13 |
1756-M02AS | 1746-A2 |
1756-M03SE | 1746-A4 |
1756-M08SE | 1746-A7 |
1756-M08SEG | 1746-BAS |
1756-M16SE | 1746-BAS-T |
1756-N2 | 1746-BLM |
1756-N2XT | 1746-BTM |
1756-OA16 | 1746-C16 |
1756-OA16I | 1746-C7 |
1756-OA8 | 1746-C9 |
1756-OA8D | 1746-F1 |
1756-OA8E | 1746-F2 |
1756-OB16D | 1746-F3 |
1756-OB16E | 1746-F4 |
1756-OB16I | 1746-F5 |
1756-OB16IEF | 1746-F8 |
1756-OB16IS | 1746-F9 |
1756-OB32 | 1746-FIO4I |
1756-OB8 | 1746-FIO4V |
1756-OB8EI | 1746-HCA |
1756-OB8I | 1746-HSCE |
1756-OC8 | 1746-HSCE2 |
1756-OF4 | 1746-HSTP1 |
1756-OF6CI | 1746-HT |
1756-OF6VI | 1746-IA16 |
1756-OF8 | 1746-IA4 |
1756-OF8H | 1746-IA8 |
1756-OG16 | 1746-IB16 |
1756-OH8I | 1746-IB32 |
1756-ON8 | 1746-IB8 |
1756-OV16E | 1746-IC16 |
1756-OV32E | 1746-IG16 |
1756-OW16I | 1746-IH16 |
1756-OX8I | 1746-IM16 |
1756-PA72 | 1746-IM4 |
1756-PA75 | 1746-IM8 |
1756-PA75R | 1746-IN16 |
1756-PAR2 | 1746-INT4 |
1756-PAXT | 1746-IO12 |
1756-PB72 | 1746-IO12DC |
1756-PB75 | 1746-IO4 |
1756-PB75R | 1746-IO8 |
1756-PBR2 | 1746-ITB16 |
1756-PBXT | 1746-ITV16 |
1756-PC75 | 1746-IV16 |
1756-PH75 | 1746-IV32 |
1756-PLS | 1746-IV8 |
1746-N2 | 1769-IT6 |
1746-N3 | 1769-L16ER-BB1B |
1746-NBC | 1769-L18ER-BB1B |
1746-NGA | 1769-L18ERM-BB1B |
1746-NGA2 | 1769-L19ER-BB1B |
1746-NGAIC | 1769-L23-QBFC1B |
1746-NGC | 1769-L23E-QB1B |
1746-NI16I | 1769-L24ER-QB1B |
1746-NI16V | 1769-L24ER-QBFC1B |
1746-NI4 | 1769-L27ERM-QBFC1B |
1746-NI8 | 1769-L30ER |
1746-NIO4I | 1769-L30ER-NSE |
1746-NIO4V | 1769-L30ERM |
1746-NLB | 1769-L30ERMS |
1746-NO4I | 1769-L33ER |
1746-NO4V | 1769-L33ERM |
1746-NO8I | 1769-L33ERMS |
1746-NO8V | 1769-L35E |
1769-L36ERM | 1756-RM |
1769-L36ERMS | 1756-L71 |
1769-OA16 | 1756-L72 |
1769-OA8 | 1756-L72S |
1769-OB16 | 1756-L73 |
1769-OB16P | 1756-L73S |
1769-OB32 | 1756-L73SXT |
1769-OB32T | 1756-L73XT |
1769-OB8 | 1756-L74 |
1769-OF2 | 1756-L75 |
1769-OF4 | 1756-L7SP |
1769-OF4CI | 1756-L7SPXT |
1769-OF4VI | 1756-LSC8XIB8I |
1769-OF8C | 1746-OW4 |
1769-OF8V | 1746-OW8 |
1769-OG16 | 1746-OX8 |
1769-OV16 | 1746-P1 |
1769-OV32T | 1746-P2 |
1769-OW16 | 1746-P3 |
1769-OW8 | 1746-P4 |
1769-OW8I | 1746-P5 |
1769-PA2 | 1746-P6 |
1769-PA4 | 1746-P7 |
1769-PB2 | 1746-QV |
1769-PB4 | 1769-IF4FXOF2F |
When choosing a PLC model, the following points are mainly considered:
1 Function selection. For small PLCs, I/O expansion modules, A/D and D/A modules, and instruction functions (such as interrupts, PID, etc.) are mainly considered.
2 Determine the number of I/O points. Count the number of I/O points of the switching quantity and analog quantity of the controlled system, and consider future expansion (generally add 10% to 20% of the spare quantity), so as to select the number of I/O points and output specifications of the PLC.
3 Estimation of memory. The memory capacity required by the user program is mainly related to factors such as the number of I/O points, control requirements, and program structure length of the system. Generally, it can be estimated as follows: storage capacity = number of digital input points × 10 + number of digital output points × 8 + number of analog channels × 100 + number of timers/counters × 2 + number of communication interfaces × 300 + spare capacity.
(3) Allocate I/O points. Assign PLC input/output points, write input/output distribution tables or draw input/output terminal wiring diagrams, then you can carry out PLC program design, and at the same time carry out control cabinet or console design and on-site construction.
(4) Program design. For more complex control systems, draw a control flow chart or a functional flow chart according to the production process requirements, and then design a ladder diagram, and then write a statement list program list based on the ladder diagram, and perform simulation debugging and modification on the program until the control requirements are met. until.
(5) Design and on-site construction of the control cabinet or console. Design the electrical layout and installation wiring diagrams of the control cabinet and console; design the electrical interlock diagrams of each part of the control system; perform on-site wiring according to the drawings and check.
(6) The overall debugging of the application system. If the control system consists of several parts, you should first perform partial debugging, and then perform overall debugging; if there are many steps in the control program, you can perform segmented debugging first, and then connect the total adjustment.
(7) Preparation of technical documents. Technical documents shall include: electrical drawings such as external wiring diagrams of programmable controllers, electrical layout diagrams, electrical components list, sequence function diagrams, annotated ladder diagrams and instructions.
Related Tags :
Copyright © 2024 Wuhan Xiatong Automation Equipment Co., Ltd.. All Rights Reserved. / XML / Privacy Policy